BOARD-LEVEL ROOT CAUSE ANALYSIS

PCB Failure Analysis Services

Preserve the evidence, isolate the failing circuit or structure, and connect the physical defect to the electrical symptom.

Confidential review · Global project support · Test path selected from evidence

X-ray inspection of a printed circuit board
Thermal analysis of a powered printed circuit board

EVIDENCE-PRESERVING ENGINEERING REVIEW

Start Your PCB Failure Review

85%Of PCB failures are detectable with proper analysis

10+Common failure modes identified

40%Reduction in rework with AI-assisted analysis

15+Industry standards for compliance

BOARD-LEVEL FAILURE MODES

Board-level failure modes
we diagnose

PCB failure analysis starts by reproducing the board-level symptom, isolating the affected circuit region and preserving solder, via, laminate and contamination evidence before rework changes it.

01

No power, shorts or open circuits

Missing rails, excessive current, open signal paths, damaged connectors or an unstable power, clock or reset domain.

02

Intermittent environmental or load-dependent faults

Board faults influenced by temperature, vibration, humidity, electrical load, flexing, contamination or time in operation.

03

Solder, BGA/QFN and assembly defects

Voids, fatigue cracks, head-in-pillow, insufficient wetting, bridges, opens, warpage and hidden area-array defects.

04

Via, trace, laminate, CAF and corrosion damage

Plated-through-hole cracks, conductor damage, delamination, dendritic growth, conductive anodic filament formation and corrosion.

BOARD-LEVEL FAULT ISOLATION

From board symptom to isolated circuit fault and physical cause

The workflow separates test-fixture, firmware and circuit behavior from the physical board evidence needed for a corrective action.

01

Record board revision and reproduce

Capture the board revision, serial number, firmware, load, environment, fixtures and repeatable failure conditions.

02

Isolate the circuit region

Compare rails, clocks, reset and signal paths with a known-good board to narrow the power domain or functional block.

03

Inspect without rework

Use visual inspection, X-ray, thermal imaging and electrical measurements before cleaning, replacing parts or cutting the board.

04

Confirm the physical site

Apply targeted cross-section, microscopy or SEM/EDS only after the suspect interconnect, via, material or component region is defined.

05

Corrective action and report

Correlate the reproduced circuit fault with assembly, material, layout or process evidence and document the corrective action.

ANALYTICAL CAPABILITIES

Core PCB failure analysis methods

Methods are combined around the symptom, board construction, component package, prior handling and evidence-preservation needs—not from a fixed checklist.

X-ray tomography cross-section of internal PCB layers
Scanning acoustic microscopy used for non-destructive PCB analysis

01 / NON-DESTRUCTIVE

X-ray and visual inspection

Reveal hidden solder joints, vias, voids, alignment, bridges, opens and internal structural features without cutting the board.

  • BGA, QFN, connector and multilayer inspection
  • 2D review or targeted tomography where appropriate
  • Evidence retained before rework or cross-sectioning

02 / LOCALIZATION

Thermal imaging and circuit isolation

Use controlled power-up, current limiting, rail measurements, signal tracing and thermal imaging to localize a short, overloaded component or unstable functional block.

  • Compare suspect and known-good boards
  • Correlate temperature with load and time
  • Protect evidence during fault localization
Thermal imaging used for PCB fault localization
Advanced microscopy used to localize PCB failure evidence
Cross-section of a multilayer printed circuit board
High-resolution SEM image of a FIB-milled PCB cross-section

03 / PHYSICAL EVIDENCE

Cross-section, SEM and EDS

Use targeted cross-sectioning, microscopy and elemental analysis to evaluate cracks, intermetallics, plating, contamination, corrosion and material interfaces at the selected failure site.

  • Use only after the target area is defined
  • Document orientation and preparation sequence
  • Correlate physical evidence with the electrical symptom

SYMPTOM-TO-TEST GUIDE

Match the PCB symptom to the first discriminating test

The first test should narrow the circuit or physical region without removing the evidence required for confirmation.

Observed board symptomUseful first checksEvidence to preserve
No power or excessive currentCurrent-limited power-up, resistance comparison, thermal imagingOriginal component state, heat pattern and rail measurements
Intermittent with flex, heat or vibrationControlled stress reproduction, continuity monitoring, X-rayFailure timing, fixture conditions and suspect interconnect area
BGA/QFN assembly concern2D/3D X-ray, optical comparison, targeted cross-sectionBoard orientation, package location and unreworked solder joints
Corrosion, CAF or material damageVisual/microscopy review, resistance testing, SEM/EDSContamination condition, humidity history and material interface
SEM and EDS evidence from an intermittent board failure

BOARD INTERCONNECT FAILURE PATH

Intermittent board failure under mechanical and thermal stress

Observed symptomA populated board passed initial testing but failed intermittently after temperature change and handling.

Circuit isolationControlled reproduction and rail measurements narrowed the fault to one functional region and suspect interconnect.

Physical confirmationX-ray and microscopy guided the selected section; SEM/EDS evidence correlated the interconnect feature with the electrical discontinuity.

Corrective actionReview the related soldering profile, assembly handling, mechanical support and inspection controls using the documented evidence.

PCB ROOT-CAUSE REPORT

PCB root-cause report and corrective actions

  • Fault location and root-cause confidence
  • Rail, signal and thermal observations
  • Annotated X-ray, cross-section or SEM/EDS evidence
  • Reproduced conditions and evidence limitations
  • Assembly, material, layout or process recommendations
  • Confidential PCB engineering report

Helpful board intake information

Board revision, operating state and prior handling help isolate the right circuit region.

  • Board part number, revision and assembly status
  • Failure symptom, reproduction rate and environment
  • Operating voltage, load, firmware and test setup
  • Manufacturing lot, field history and prior rework
  • Known-good board or comparison data
  • Photos, logs, schematics, Gerbers or test files

BEFORE YOU SUBMIT

PCB failure analysis FAQ

Still unsure which test method fits? Start with the symptom and available evidence; the analysis path can be defined during review.

What information should I send with the failed PCB?

Send the board number and revision, failure symptoms, operating conditions, reproduction rate, handling or rework history and any available photos, logs, schematics or known-good comparison data.

Should the failed board be repaired before analysis?

Usually not. Cleaning, component replacement, reflow or probing can change or remove evidence. Record the current condition before altering the suspect area.

Can you investigate intermittent failures?

Yes. We can reproduce or bound faults using controlled temperature, load, timing, flexing and electrical conditions, then correlate the symptom with thermal, electrical or physical evidence.

What is included in the final report?

The report documents samples, test conditions, analysis sequence, annotated observations, findings, limitations and engineering recommendations appropriate to the available evidence.

START WITH THE BOARD, SYMPTOM AND OPERATING STATE

Need an engineer to review your failed PCB?

Share the board revision, failure symptom, operating state and available evidence. We will recommend the next PCB fault-isolation step.

Scroll to Top

Instant Quote

Scan the code