Stromteilungsrechner

Berechnen Sie mit unserem Stromteiler-Rechner, wie sich der Strom zwischen parallelen Widerständen aufteilt. Erhalten Sie sofortige Ergebnisse, Schaltpläne und Echtzeit-Diagramme.

Circuit Inputs

R1:
R2:

Calculated Branch Currents

Total Equivalent Resistance

How It Works: The Current Divider Rule

The Current Divider Rule (CDR) is a fundamental principle in electronics that describes how electric current is distributed among parallel branches in a circuit. The current divides in inverse proportion to the resistance of each branch—meaning the path of least resistance gets the most current.

Interactive Circuit Diagram

The General Formula

To find the current (Ix) flowing through a specific resistor (Rx), you can use the general current divider formula:

Ix = Itotal × (Req / Rx)

Where:

  • Ix is the current in the branch with resistor Rx.
  • Itotal is the total current entering the parallel combination.
  • Req is the total equivalent resistance of all parallel resistors.
  • Rx is the resistance of the branch you are calculating for.

Two-Resistor Shortcut

For the common case of just two parallel resistors (R1 and R2), the formula for the current in the first branch (I1) simplifies to:

I1 = Itotal × (R2 / (R1 + R2))

Visualize the Current Division

This chart provides a dynamic, real-time visualization of how the total current is distributed among the different resistor branches. Change the input values above to see how the chart reacts instantly.

Frequently Asked Questions

A current divider splits current between parallel components, while a voltage divider splits voltage between series components. The key difference is the circuit configuration: parallel for current division, and series for voltage division.
The CDR applies to linear, bilateral circuits. You cannot use it directly if the circuit contains non-linear elements like diodes or transistors in the parallel branches, or if it has dependent sources. In those cases, other analysis techniques like nodal analysis are needed.
Current dividers are fundamental in many areas. They are used in transistor biasing circuits to set the proper operating conditions. They are also integral to ammeters with multiple ranges, where they are used as shunts to divert a specific fraction of the current away from the sensitive meter movement. Additionally, they are found in various sensor circuits.

Built for educational and developmental purposes.

Verwandte PCB-Tools

3D illustration of a copper wire with measurement indicators for calculating electrical resistance and resistivity

Drahtwiderstandsrechner

Berechnen Sie den Drahtwiderstand basierend auf Material, Länge, Durchmesser und Temperatur. Enthält eine AWG-Tabelle, Daten zur spezifischen Widerstandsfähigkeit und interaktive

Weiterlesen »
3D visualization of a bandpass filter frequency response showing a specific range of signal transmission

Bandpassfilter-Rechner

Interaktiver RLC-Bandpassfilter-Designer. Berechnen Sie die Mittenfrequenz, Bandbreite und den Q-Faktor mit Echtzeit-Bode-Diagrammen und Schaltplänen.

Weiterlesen »
LED Resistor Calculator with a bright red LED and a resistor on a circuit board.

LED-Widerstandsrechner

Nutzen Sie unseren kostenlosen LED-Widerstandsrechner, um den perfekten Widerstand für Ihre LED-Schaltung zu finden. Erhalten Sie genaue Werte für einzelne

Weiterlesen »
3D visualization of color-coded axial resistors and SMD components for resistance value calculation

Widerstandsrechner

Berechnen Sie den Gesamtäquivalentwiderstand für Reihen- und Parallelschaltungen. Mit interaktiven Diagrammen, Schritt-für-Schritt-Formeln und ausgearbeiteten Elektronikbeispielen.

Weiterlesen »
3D visualization of a high-pass filter frequency response curve illustrating low-frequency attenuation and high-frequency transmission

Hochpassfilter-Rechner

Berechnen Sie die Grenzfrequenz für einen RC-Hochpassfilter mit unserem interaktiven Tool. Enthält ein Bode-Diagramm, einen Schaltplan und wichtige HPF-Formeln für

Weiterlesen »
3D illustration of a 555 Timer IC generating square wave pulses for frequency and duty cycle calculation

555 Timer-Rechner

Berechnen Sie ganz einfach die Ausgangsparameter für astabile und monostabile 555-Timer-Schaltungen. Dieses Online-Tool liefert sofortige Ergebnisse für Frequenz, Periode, Tastverhältnis

Weiterlesen »
Nach oben scrollen

Instant Quote